ANNUAL ENERGY
CONSUMPTION- 91.5 Mbtu
(Per heating season @ 70°F indoor temp.)
|
ANTICIPATED
HEATING COST- $1126.36
(Per heating season @ $.147 per kwh)
Cost To Environment- 10,458 Lbs.
(CO2 Emissions Per Year) |
|
|
| |
|
|
| BUILDING ENVELOPE: |
|
Energy Star
Recommendation |
| |
|
|
|
R-38 kraft faced fiberglass with eave baffles |
|
R-38 |
| |
|
|
Above Gnd. Exterior Walls |
|
R-19 kraft faced fiberglass batts within 2 x 6 framing cavities
Vapor semi-permeable structural OSB exterior sheathing
Air and water infiltration barrier- all exterior walls & gables wrapped with vapor permeable spun high density polyethylene fiber building wrap |
|
|
R-13 |
| |
|
|
| Windows & Full Glass Doors |
U.30/ SHGC .40 Pella Architect Series casement- dual glazed. Argon gas filled with metallic oxide low emissivity coating
|
|
|
≤U.40/≤SHGC.45 |
| |
20% glazed surfaces as a percent of conditioned living area |
≤21% |
| |
|
|
| Exterior Doors |
U.15 Thermatru fiberglass clad polyurethane foam core with tight seal weather stripping |
|
| |
|
|
| Basement Walls |
R-13 kraft faced fiberglass insulation affixed within 2x4 perimeter wall cavities. Foundation ten inch thick continuous reinforced concrete wall. R-19 two by six rear exterior walls |
|
|
R-13 |
| |
|
|
| Basement Slab |
R-7.5 polystyrene foam board horizontally placed underneath entire basement slab. One half inch polystyrene capillary and expansion break entire perimeter |
|
R-10 @2’horizontal |
| |
|
|
| Envelope Air Infiltration |
To be tested as specified by “Blower Door” testing and analysis
|
≤7ach50 pascels |
| |
|
|
| Roof Eave Overhang |
2’-0” overhang for summer shading, winter solar gain, and roof run off protection |
|
1’-9” optimal
(window header height= 1’-1”) |
| |
Complete three page Home Energy Analysis available pre-construction to facilitate energy related systems selection. |
|